Communication Server 1000M and Meridian 1
5
Set the COM port on the maintenance terminal as follows:
Terminal type: VT100
Speed: 9 600
Data bits: 8
Parity: none
Stop bits: 1
Flow control: none
Note: The CP PM Signaling Server is shipped with the Admin Serial port
set to 9600 Bit/s. Other available speeds are 19 200, 38 400, and 115 200
Bits. You can change the port speed using the maintenance terminal. To
verify or change the baud rate on a Nortel CP PM Signaling Server, see
Signaling Server: Installation and Commissioning (NN43001-312).
6
Configure the Signaling Server maintenance terminal. Refer to Signaling
Server: Installation and Commissioning (NN43001-312).
Complete Procedure 56 to connect a Nortel CP PM Signaling Server (model
NTDW61BAE5) to the ELAN and TLAN subnets of a CS 1000E system.
Procedure 56
Connecting a CP PM Signaling Server to the ELAN and TLAN subnets of
a CS 1000E system
1
Connect the Signaling Server to the ELAN subnet.
if the Call Server is not connected to the Media Gateway Controller
(MGC)
— Insert the end of one of the 25-cm RJ-45 CAT5 Ethernet cables
shipped with the server (NTDU0606E6) into the ELAN network
interface port (ELAN port) on the faceplate of the server
— insert the other end of the 25-cm RJ-45 CAT5 Ethernet cable
into the MGC ELAN Ethernet port
if the Call Server is connected to the MGC
Installing a Signaling Server
End of Procedure