18. Follow instructions in the manual for installation into a EP28-2 for exact
measurements for installation of the outside firebox to the surround.
EP28 Firebox
5 5/8"
143mm
Leg Setting / Outer Shell Position
19. The top panel of the ZC surround may be removed to ease the installation
of the venting - reinstall top panel after venting is installed.
* Extra venting may be required.
E18 Insert
20. Follow instructions in the installation into existing unit section in the
manual to complete the install of inner firebox.
Follow Step 21 before installing faceplate.
Collar Plate Setting / Vent position
24
|
Regency
E18E-11 Gas Fireplace Insert
®
EP28 Installation Specifications
8 7/16"
215mm
1 7/16"
37mm
A
EP28 Firebox
B
21. Install lower trim piece with 2 (904-897) screws to the bottom of the
ZC surround before installing faceplate.
Leg height setting
Flex Adaptor Length
1/4"
6mm
DETAIL A
SCALE 1 : 4
4 1/8"
105mm
Adaptor Plate
fastener setting
DETAIL B
SCALE 1 : 4