Regency Sunrise E33S Installation Manual

Regency gas insert installation manual
Hide thumbs Also See for Sunrise E33S:

Advertisement

Quick Links

E33 Sunrise
MODELS:
www.regency-fi re.com
WARNING:
If the information in these instructions are not followed exactly,
a fi re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed
installer, service agency or the gas supplier.
Tested by:
918-747
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
Gas Insert
E33S-NG1 Natural Gas
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
E33S-LP1 Propane
FOR YOUR SAFETY
What to do if you smell gas:
Owners &
Installation Manual
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you
cannot reach your gas
supplier, call the fi re department.
02/16/09

Advertisement

Table of Contents
loading

Summary of Contents for Regency Sunrise E33S

  • Page 1 E33 Sunrise MODELS: E33S-NG1 Natural Gas www.regency-fi re.com WARNING: If the information in these instructions are not followed exactly, a fi re or explosion may result causing property damage, personal injury or loss of life. FOR YOUR SAFETY Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2 As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your FPI Fireplace. Regency E33S-1 Sunrise Gas Insert ®...
  • Page 3: Table Of Contents

    Optional Remote Control ...16 Optional Wall Thermostat ...16 Glass Crystal or Ceramic Stone Installation ...17 Glass Door Installation ...17 Faceplate & Door Frame Installation ...18 Optional Hearth Trim Installation ...20 Regency E33S-1 Sunrise Gas Insert ® TABLE OF CONTENTS OPERATING INSTRUCTIONS Final Check...21 First Fire ...21...
  • Page 4: Safety Label

    The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed. Regency ® E33S-1 Sunrise Gas Insert...
  • Page 5: Requirements

    (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. Regency ® E33S-1 Sunrise Gas Insert...
  • Page 6: Unit Dimensions

    UNIT DIMENSIONS Regency ® E33S-1 Sunrise Gas Insert...
  • Page 7: Installation

    4,500' (0-1370m). Electrical: 120V A.C. system. Circulation Fan: Variable speed, 127 CFM. Vent System: 3" co-linear aluminum fl ex. Cobalt Blue Glass Crystals Regency ® E33S-1 Sunrise Gas Insert INSTALLATION INTO A SOLID FUEL BURNING FIREPLACE OR FACTORY BUILT FIREPLACE...
  • Page 8: Installation Checklist

    MINIMUM FIREPLACE OPENING The minimum fi replace opening is shown in the following diagrams: Width (at front) 32-1/4" (819mm) Width (at rear) 25" (635m) Depth 16-3/4" (425mm) Height 24-3/16" (614mm) Regency ® E33S-1 Sunrise Gas Insert...
  • Page 9: Minimum Clearances To Combustibles

    Alcove Depth 36" (914 mm) * Alcove side wall must have a min. of 8" clearance on one side. COMBUSTIBLE MANTEL CLEARANCES Regency ® E33S-1 Sunrise Gas Insert INSTALLATION Due to the extreme heat this fi replace emits, the mantel clearances are critical.
  • Page 10: Gas Connection

    2) Mill-pac may be used instead of high tempture silicone and screws may be used instead of gear clamps at connections of liner to inlet and vent collars. Regency ® E33S-1 Sunrise Gas Insert...
  • Page 11: Gas Pipe Pressure Testing

    (clockwise) with a 1/8" fl at screwdriver. Note: Screw should be snug, but do not over tighten. Regency ® E33S-1 Sunrise Gas Insert SIT VALVE DESCRIPTION 1) Gas on/off knob...
  • Page 12: Conversion From Ng To Lp

    INSTALLATION CONVERSION KIT #434-969FROM NG TO LP Regency ® E33S-1 Sunrise Gas Insert...
  • Page 13 INSTALLATION Regency ® E33S-1 Sunrise Gas Insert...
  • Page 14 INSTALLATION Regency ® E33S-1 Sunrise Gas Insert...
  • Page 15: Wiring Diagrams

    This heater does not require a 120V A.C. supply for operation. However, a 120V A.C. power supply is needed for the fan/blower operation. NATURAL GAS Regency ® E33S-1 Sunrise Gas Insert WIRING DIAGRAMS Caution: Ensure that WARNING: Electrical Grounding Instructions...
  • Page 16: Optional Remote Control

    Recommended Maximum Lead Length (Two-Wire) When Using Wall Thermostat (CP-2 System) Wire Size Max. Length 14 GA. 50 Ft. 16 GA. 32 Ft. 18 GA. 20 Ft. 20 GA. 12 Ft. 22 GA. 9 Ft. Regency ® E33S-1 Sunrise Gas Insert...
  • Page 17: Glass Crystal Or Ceramic Stone Installation

    Refer to Diagram 3. Secure door by fastening with two screws located at bottom of glass door, refer to Diagram 1. Diagram 1 Regency ® E33S-1 Sunrise Gas Insert INSTALLATION Optional Ceramic Stones shown on Burner...
  • Page 18: Faceplate & Door Frame Installation

    4) Align the faceplate tabs with the tab brackets on the inside top of the fi rebox and slide in place. NOTE: For easy installation do not force both tabs in at the same time, stagger from left to right. Fan Rheostat Tab Brackets Faceplate Tabs Regency ® E33S-1 Sunrise Gas Insert...
  • Page 19 7) Secure the hinge to the bottom fl ange of the fi rebox with 2 screws from step 6. Repeat for other side. Spacer Screw Regency ® E33S-1 Sunrise Gas Insert INSTALLATION 8) Align the left and right side hinge with the screw holes in the bottom louver and secure in place using 3 screws per side.
  • Page 20: Optional Hearth Trim Installation

    (3 per side) as shown in diagram 1. The holes in the Hearth Trim are oblong so the trim can be adjusted inwards or outwards as needed to suit fi nishing. Diagram 2 Regency ® E33S-1 Sunrise Gas Insert...
  • Page 21: Operating Instructions

    The glass should be cleaned or the fi lm will bake on and become very diffi cult to remove. Use a non-abrasive cleaner and NEVER clean the glass while it is hot. Regency ® E33S-1 Sunrise Gas Insert OPERATING INSTRUCTIONS OPERATING...
  • Page 22: Copy Of Lighting Instruction Plate

    Unit Body and Firebox: Different types and thicknesses of steel will expand and contract at different rates resulting in some "cracking" and "ticking" sounds which will be heard throughout the cycling process. Regency ® E33S-1 Sunrise Gas Insert...
  • Page 23: Maintenance

    C L O T H I N G O T H E R FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE. Regency ® E33S-1 Sunrise Gas Insert 6) Each time the appliance is lit, it may cause condensation and fog the glass.
  • Page 24: Valve Tray Replacement

    7) Remove the burner by undoing the 2 screws shown. Carefully lift the burner up and out ensuring not to spill glass crystals. 8) Carefully set aside the burner and glass crystals. Glass Door Back Shield Burner Regency ® E33S-1 Sunrise Gas Insert...
  • Page 25 10) Disconnect the ON/OFF connector wires from the valve. NOTE: For LP units disconnect the DC Sparker ignitor wire from the valve. ON/OFF Wires Regency ® E33S-1 Sunrise Gas Insert 11) Remove the valve tray by undoing the 17 screws.
  • Page 26: Fan Replacement

    8) Carefully set aside the burner and glass crystals. Glass Door Burner 9) Remove the base cover by lifting up from the back and maneover out. Base Cover Regency ® E33S-1 Sunrise Gas Insert...
  • Page 27 10) Remove the fan access plate by undoing the 12 screws shown. 11) Remove the 2 screws that hold the pilot assembly in place and lift forward as shown below. Regency ® E33S-1 Sunrise Gas Insert MAINTENANCE 12) Remove the 2 screws that hold the fan in place and slide the fan towards the front of the unit.
  • Page 28: Parts List

    Orifi ce #54 - LP 936-170 Orifi ce Gasket 79) 341-525 Burner Assy - NG/LP 80) 340-149 Back Shield 81) 340-155 Pilot Hood 82) * Base Cover 918-747 Manual * Not available as a replacement part. MAIN ASSEMBLY Regency ® E33S-1 Sunrise Gas Insert...
  • Page 29: Contemporary Faceplate & Door Frame

    91) * Door Frame 92) * Bottom Louver 93) * Hinges 910-246 Burner ON/OFF Switch 910-330 Fan Speed Control 120V 904-569 Fan Speed Control Knob * Not available as a replacement part. Regency ® E33S-1 Sunrise Gas Insert PARTS LIST...
  • Page 30 NOTES Regency E33S-1 Sunrise Gas Insert ®...
  • Page 31: Warranty

    It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer defect. The authorized selling dealer is responsible for all in-fi eld service work carried out on your Regency product. FPI will not be liable for results or costs of workmanship from unauthorized service persons or dealers.
  • Page 32 ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Regency and Sunrise are trademarks of FPI Fireplace Products International Ltd. © Copyright 2009, FPI Fireplace Products International Ltd. All rights reserved. online at ® Printed in Canada...