E18E INSTALL SPECIFICATIONS
See Installation of E18E into Existing Units for General Installation Guidance.
This install of the E18E uses a full length 4" liner.
The Length of 4" Flex needed depends on the height of the B vent chimney.
Secure top plate to firebox w/4 screws.
Secure vent slide plate to flex pipe with 4
screws
Montigo 36SR Installation Specifications
36SR Firebox
Leg Setting / Outer Shell Position
1. Loosen 2 x Phillips screws on both right and left legs.
2. See above diagram below for required leg setting.
3. Install with supplied Phillips screws to prepunched holes and tighten previous screws that were loosened in Step 1.
4. Keep left side leg loose until outer firebox is in position in ZC box - to allow adjustment of gas line.
E18 Insert
36SR Firebox
Leg Setting / Outer Shell Position
E18 Insert
6 15/16"
176mm
A
36SR Firebox
6 15/16"
176mm
A
36SR Firebox
B
Collar Plate Setting / Vent position
6 3/8"
162mm
1 9/16"
40mm
Leg height setting
6 3/8"
162mm
1 9/16"
40mm
Leg height setting
Flex Adaptor Length
1 1/2"
37mm
Set to this
hole
DETAIL A
SCALE 1 : 4
Right side shown
3"
76mm
Regency
E18E-11 Gas Fireplace Insert
®
Flex Adaptor Length
installation
DETAIL A
SCALE 1 : 4
3"
76mm
Set to this
Adaptor Plate
hole
fastener setting
DETAIL B
SCALE 1 : 4
|
47