SAFETY SWITCHES

The E18E uses two safety switches to maintain proper operation.
The first is a Spill Switch which will shut off the appliance if continuous spilling of exhaust gas from the drafthood occurs. The spill switch will shut off the Main
Burner but not the Pilot. This switch resets automatically, if the problem persists the appliance will cycle on and off. If this occurs, shut the unit off and contact
a technician.
The second is a Primary Limit Switch. This switch confirms that the circulation fan is operating normally. If for any reason the circulation fan fails, the Primary
Limit Switch will turn off the Main Burner but not the Pilot before the appliance becomes too hot. This switch is automatic resetting, so if the problem persists
you will see your appliance cycling on and off. If this occurs shut the unit off and contact a technician.

OPERATION CONTROLS

FIREPLACE CONTROLS

The E18E has 3 controls for controlling flame height, fan
speed and flame on/off. The fan on the E18E is designed
to come on once the fireplace has reached a pre-deter-
mined temperature, and to go off once the temperature
has dropper following use.
The speed of the fan can be varied by adjusting the Fan
Speed Control dial up or down. These controls are located
to the left side of the Surround Panels.
Providing that the pilot system is in standing mode, the
main burner can be turned on or off by way of a
switch located just below the Fan Speed Control dial.
See the Lighting Instruction section in this manual
for information on lighting the pilot.
The flame height can be adjusted from minimum to maxi-
mum by way of an adjustment knob on the Control Valve,
located behind the Access Panel.
The Access Panel is held in place by magnets and can
simply be lifted away from the unit and set aside.
Fan Speed Control
On / Off Switch
Flame Control
Flame control
Regency
installation
Access Panel
Diagram 18.1
E18E-11 Gas Fireplace Insert
®
Fir
The
con
and
E1
the
det
off
dro
The
by
dia
loc
Su
Pro
sta
can
sw
Spe
Ins
for
The
fro
of a
Co
Acc
hel
sim
and
|
79

Advertisement

Table of Contents
loading

This manual is also suitable for:

Energy e18eEnergy e18e-lp11

Table of Contents