15. Install supplied support section with 8 screws to reinforce
Firesong firebox. (See Diagram 10.14).
Diagram 10.14
16. Repeat Steps 14 & 15 on left side.
17. Remove existing Firesong rating plate from cut out firebox.
This rating plate must be retained and affixed to the unit. (See
Diagram 10.15 and 10.16).
Diagram 10.15
18. Final modified firebox should look like Diagram 10.16
NOTE: Shown with flue collar and 6" length of flex installed.
Firesong decal affixed
IMPORTANT NOTE:
Separate inner and outer firebox on E18E (see instructions in this
manual) Before installing outer firebox - lay on a flat surface and
trim off 1-1/4" of each firebox fastening flange as shown below.
Regency
installation
Diagram 10.16
E18E-11 Gas Fireplace Insert
®
|