28 F / 28 F2 INSTALLATION SPECIFICATIONS

E18E INSTALL SPECIFICATIONS
See Installation of E18E into Existing Units for General Installation Guidance for Vent Configuration.
This install of the E18E uses Vent Connection Type A.
The Length of 4" Flex needed is 2-5/8" semi-expanded. Secure flue adapter top plate to under side of existing firebox using 4 self taping
screws.
Secure top plate to firebox w/4 screws.
Secure vent slide plate to flex pipe with 4
screws
28-F / 28F-2 Firebox
Leg Setting / Outer Shell Position
1. Loosen 2 x Phillips screws on both right and left legs.
2. See above diagram below for required leg setting.
3. Install with supplied Phillips screws to prepunched holes and tighten previous screws that were loos-
ened in Step 1.
4. Keep left side leg loose until outer firebox is in position in ZC box - to allow adjustment of gas line.
E18 Insert
38
|
Regency
E18E-11 Gas Fireplace Insert
®
28-F / 28F-2 Firebox
Leg Setting / Outer Shell Position
E18 Insert
Collar Plate Setting / Vent position
28-F & 28F-2 Installation Specifications
6 1/16"
155mm
A
28-F / 28F-2 Firebox
6 1/16"
155mm
A
B
7 3/16"
183mm
1 1/2"
39mm
Leg height setting
Right side shown
Flex Adaptor Length
7 3/16"
183mm
1 1/2"
39mm
Leg height setting
28-F / 28F-2 Firebox
Flex Adaptor Length
Set to this
hole
DETAIL A
SCALE 1 : 4
2 5/8"
66mm
DETAIL A
SCALE 1 : 4
2 5/8"
66mm
Set to this
Adaptor Plate
hole
fastener setting
DETAIL B
SCALE 1 : 4