INSTALLATION OF THE E18E INTO EXISTING UNITS
STEP #1: VENT CONNECTION TYPE A
1. Attach the Flex Vent Section to the Adaptor Plate using 3
self drilling sheet metal screws.
2. Using 4 Sheet Metal Screws, attach the Adaptor Plate,
Vent Section and Adaptor Plate Gasket to the top of the
existing Fire Box.
See specific instructions to your installation to determine what
position the Adaptor Plate should be located.
3. Attach the Slide Plate Retainer to the Vent Slide Plate using the
setting outlined in your unit specific installation guide.
4. Using the 3 self drilling sheet metal screws,
attach the Vent Slide Plate to the Flex Vent Section
THE APPLIANCE MUST
NOT BE CONNECTED TO A
CHIMNEY FLUE SERVING
A SEPARATE SOLID FUEL
BURNING APPLIANCE.
STEP #1: VENT CONNECTION
(FIRESONG 120N)
1. Attach the Flex Vent Section to the Adaptor Plate using 3
self drilling sheet metal screws.
Adaptor Plate Gasket
Adaptor Plate
Slide Plate Retainer
installation
Flex Vent Section
Vent Slide Plate
Diagram 11.1
Diagram 11.2
Regency
E18E-11 Gas Fireplace Insert
®
Sheet Metal
Screws
|
55