Connecting example
Connect all the projectors to be linked in a loop by daisy chain connection when using the contrast
synchronization function/shutter synchronization function. The number of linked projectors is limited to the
maximum of 64 projectors.
r For <MULTI PROJECTOR SYNC IN>/<MULTI PROJECTOR SYNC OUT> terminals
Connecting terminals of the synchronization source
Connecting terminals of the projector to
synchronize
Note
f The contrast synchronization function and the shutter synchronization function can be used simultaneously.
f For details on the settings of the contrast synchronization function and the shutter synchronization function, refer to the [PROJECTOR
SETUP] menu → [MULTI PROJECTOR SYNC] (x page 159).
f The menu items in the [PROJECTOR SETUP] menu → [MULTI PROJECTOR SYNC] are common with the following setting items.
g The [PICTURE] menu → [DYNAMIC CONTRAST] → [USER] → [MULTI PROJECTOR SYNC]
g The [DISPLAY OPTION] menu → [SHUTTER SETTING] → [MULTI PROJECTOR SYNC]
f If there are any projectors which you do not want to synchronize within the linked projectors, set [CONTRAST SYNC] and [SHUTTER
SYNC] to [OFF] individually.
f The shutter synchronization function will operate even when there are different models within the linked projectors. However, the
synchronization function will not operate when there is a DLP projector that is constructed with three DLP chips within the linked projectors.
f To use the <MULTI PROJECTOR SYNC IN>/<MULTI PROJECTOR SYNC OUT> terminals, set the [PROJECTOR SETUP] menu → [MULTI
PROJECTOR SYNC] → [TERMINAL SELECT] to [BNC].