Vision Settings
1. Click on "Sync Options..." in the Options menu.
2. Click on "MIDI Time Code" in the pop-up menu next to
Receive Sync.
3. Click on "30 fps, non drop" in the pop-up menu next to
SMPTE Format.
4. Click on "OK."
VS-1824 Settings
1. Hold [SHIFT] and press [EXT SYNC].
2. Move the cursor to Sync Source and use the TIME/
VALUE dial to select "INT."
3. Move the cursor to Sync Gen and use the TIME/VALUE
dial to select "MTC."
4. Move the cursor to Sync MTC Type and use the TIME/
VALUE dial to select "30."
5. Press [F6 (Exit)], then press [F4 (MIDI)].
6. Move the cursor to Device ID and use the TIME/VALUE
dial to select "17."
7. Move the cursor to MIDI Thru and use the TIME/
VALUE dial to select "Out."
8. Move the cursor to SysEx Rx and use the TIME/VALUE
dial to select "On."
9. Move the cursor to MMC and use the TIME/VALUE dial
to select "Slave."
10. Press [PLAY (DISPLAY)] to return to the Playlist display.
Click on the Play icon in Vision. The VS-1824 should begin
playback in sync with Vision. If not, check the MIDI
connections and OMS settings in your computer.
Chapter 16 Using Software Sequencers
VS-1824 as Master Device
The next example uses MTC, with the VS-1824 controlling
the playback of Vision.
Connections
1. Connect the MIDI OUT port of the VS-1824 to the MIDI
IN port of your MIDI interface.
Vision Settings
1. Click on "Sync Options..." in the Options menu.
2. Click on "MIDI Time Code" in the pop-up menu next to
Receive Sync.
3. Click on "30 fps, non drop" in the pop-up menu next to
SMPTE Format.
4. Click on "Remote Start," so it is checked.
5. Click on "OK."
VS-1824 Settings
1. Hold [SHIFT] and press [EXT SYNC].
2. Move the cursor to Sync Source and use the TIME/
VALUE dial to select "INT."
3. Move the cursor to Sync Gen and use the TIME/VALUE
dial to select "MTC."
4. Move the cursor to Sync MTC Type and use the TIME/
VALUE dial to select "30."
5. Press [F6 (Exit)], then press [F4 (MIDI)].
6. Move the cursor to Device ID and use the TIME/VALUE
dial to select "17."
7. Move the cursor to MIDI Thru and use the TIME/
VALUE dial to select "Out.
8. Press [PLAY (DISPLAY)] to return to the Playlist display.
Click on the Play icon in Vision, it will start to flash. Press
[PLAY] on the VS-1824 and Vision should start playback in
sync with the VS-1824. If not, check the MIDI connections
and OMS settings in your computer.