Table2.6 Restrictions on system configuration, available base units, extension cables, and power supply modules
CPU number
CPU module 1: CPU No.1, CPU module 2: CPU No.2, CPU module 3: CPU No.3
Maximum number of
extension stages
Q32SB
Maximum number of
mountable I/O
Q33SB
modules
Q35SB
Available main base
unit model
Available power
supply module model
Precautions
2
- 21
2.1 System configuration
2.1.2 System configuration using High Performance model QCPU or Process CPU as CPU No.1
POINT
When the multiple CPU system is configured using the High Performance model
QCPU as the CPU No.1, only the following CPU modules can be used as the
CPUs No.2 and 3.
• High Performance model QCPU
• Universal model QCPU (except Q02UCPU)
• C Controller module
(b) Outline of system configuration
Slim type main base unit .........32-point module is mounted on each slot.
Q35SB(5 slots occupied)
CPU
Slim type power
supply module
CPU module 1
Diagram 2.12 System configuration example for using Q3 SB
• The slim type main base unit has no extension cable connector.
The extension base unit and GOT cannot be bus-connected.
• Since the current consumption of the CPU module exceeds the rated output
current of the power supply module (Q61SP), mounting 4 CPU modules is not
allowed.
• When using the C Controller module, mounting three CPU modules is not
allowed.
• "No. of CPUs" indicates the number of CPU modules set in the "No. of PLCs" of
the GX Developer.
0
1
2
3
4
...... Slot number
...... I/O number
CPU module 3
CPU module 2
Extension not allowed
3 - (No. of CPUs)
4 - (No. of CPUs)
6 - (No. of CPUs)
Q32SB, Q33SB, Q35SB