4. DC Voltage
A measurement of DC voltage is made between the particular test point and the frame unless
otherwise specified by note and test data. The measured DC voltage is in the range below:
Table 1
LVPS
Voltage
Level
LVPS
+5VDC
(H)
+24VDC
(H)
Version 1.0
WC 5022/5024
Range
+4.85 - +5.35VDC
+22.28 - +25.72VDC
5. Other Descriptions
DC330 Input Component Voltage Level
The voltage levels (H/L) shown on the BSDs are the levels that are measured by the
tester.
Some of them are therefore different from H/L displayed on the PSW.
Wire Color
Wires are distinguished by color in port of the BSDs for this model.
The colors of wires are shown below the signal lines in their respective abbreviations
listed below:
Table 1
Abbreviation
Color
BRN
BROWN
RED
RED
ORN
ORANGE
YEL
YELLOW
GRN
GREEN
BLU
BLUE
VIO
VIOLET
GRY
GRAY
WHT
WHITE
BLK
BLACK
GN/YL
GREEN/YELLOW
PNK
PINK
SKY
SKY
Figures on the BSDs
The grayed-out portion of the figure shows the path from Motoror Solenoid to parts to
drive.
06/2014
7-31
Wiring Data
4. DC Voltage