045-310 Image Ready Error
BSD-ON: CH3.3
Unable to send the Image-valid signal cannot within the specified time.
NOTE: When the attempt to expand the image has failed, [016-776 Marker Code Detection
Fail] occurs after the recover operation.
Cause/Action
1.
Check the following:
The Net Cable for poor connection.
The USB Cable (Local) for poor connection.
The connector ( P/J425) between the ESS/MCU PWB and the NET I/F PWB for poor
contact.
2.
Upgrade the Controller Firmware.
ADJ 18.2.3
3.
If no problem is found, replace the ESS/MCU PWB. (PL 18.3)
Version 1.0
WC 5022/5024
045-313 IOT Logic Fail
BSD-ON:-
The IOT Software error was detected.
Cause/Action
1.
Turn the power OFF and ON.
2.
Install the correct version of the IOT firmware.
3.
If the problem persists, replace the ESS/MCU PWB. (PL 18.3)