093-312 Toner Dispense Motor Rotation Fail
BSD-ON: CH9.2
Regardless of low usage of toner from Toner Cartridge, it was detected to be empty.
Cause/Action
Check the following:
The Toner Cartridge for improper installation
The Toner Dispense Motor (Output Check [092-001]) for operation failure. (PL 8.2)
The Toner transport path for Toner blockage.
The Drive Gear for wear and damage.
If no problem is found, replace the following parts in sequence:
Toner Cartridge (PL 8.1)
ESS/MCU PWB (PL 18.3)
Version 1.0
WC 5022/5024
093-400 Toner Near Empty
BSD-ON: CH9.2
The Toner Cartridge needs to be replaced soon.
Cause/Action
The Toner Cartridge needs to be replaced soon. Replace the Toner Cartridge as required. (PL
8.1)