Adjustment
1.
Input the NVM [711-141].
2.
Adjust to the specified range (10 +/-1.9 mm).
If the distance between the Lead Edge and the reference value is
•
12.0 mm or higher, increase the NVM value.
•
8.0 mm or lower, decrease the NVM value.
(NVM1Step=0.1mm)
3.
Repeat the procedure until the value is within the specified range (10 +/-1.9 mm).
As there will be differences in the Regi according to the ratio, adjust the following NVM.
Table 2
Basic Scan Speed
NVM
[mm/s]
NVM [711-022]
165.0
NVM [711-024]
82.5
Version 1.0
WC 5022/5024
Reduce / Enlarge
100.0%
Other than 100.0%
06/2014
4-111
Repairs and Asdjustments