6.5.2.3 Analog Monitor
Purpose
Monitors the A/D converted analog value of the sensor while each component is being oper-
ated.
NOTE: For more details on the Analog Monitor Code, refer to 6.3.3.2 in Chapter 6.
Procedure
1.
Enter the CE Diag Mode.
2.
Input the Chain-Link No. and press <Start>.
3.
The current analog value is displayed.
When the Analog Monitor is in progress, the message [In progress] is displayed on
the UI.
The analog value of the monitored component is displayed on the UI with a refresh
rate of 3 times per second
It is not possible to input several Chain-Link No. at the same time to perform moni-
toring.
As there is no item with automatic timeout, the process will run until <Stop> is
pressed.
4.
Pressing <Stop> displays [Done] on the UI.
5.
Pressing <Clear (C)> returns you to the [Diagnostics Mode Base] screen.
General
6.5.2.3 Analog Monitor
6.5.2.4 NVM Initialize
Purpose
Returns the NVM to its default values.
Procedure
1.
Enter the CE Diag Mode.
2.
Input the Chain-Link No. of the item to initialize.
Chain-Link Type
999-990
NVM Initialize - Controller
999-991
NVM Initialize - Network
999-992
NVM Initialize - IIT
999-993
NVM Initialize - MCU
999-994
NVM Initialize - DADF
999-995
NVM Initialize - Fax
999-999
NVM Initialize - All Area
3.
Pressing <Start> displays the initialization confirmation on the UI.
To initialize, press <Start> to start the initialization.
To cancel initialization, press <Clear (C)> to return to the [Diagnostics Mode Base]
screen.
4.
Perform the initialization. When the initialization has completed, [Done] will be displayed.
5.
Pressing <Clear (C)> returns you to the [Diagnostics Mode Base] screen.
06/2014
6-106
Table 1
Overview
Initializes the NVM of the Controller.
Initializes the NVM of the Network.
Initializes the NVM of the IIT.
Initializes the NVM of the MCU.
Initializes the NVM of the DADF.
Initializes the NVM of the Fax.
Initializes the NVM of all areas.