Table 3-17
Event Messages
continued
Event Type
Processor
Correctable Error
Threshold exceeded
Uncorrectable Error
Host Bus Error
PCI Bus Error
Power Subsystem
Power Supply Failure
Power Supply Inserted
Power Supply Removed
Power Supply
Not Redundant
System Configuration
Battery Low
Power Module Failure
Power Module Failure
Automatic Server Recovery-2
System Lockup
Operating System
System Crash
Automatic OS
Shutdown
Event Message
Processor Correctable error Threshold
passed (Slot X, Socket X)
Unrecoverable Host Bus Data Parity Error
Unrecoverable Host Bus Address Parity
Error
PCI Bus Error (Slot X, Bus X, Device X,
Function X)
System Power Supply Failure (Power
Supply X)
System Power Supply Inserted (Power
Supply X)
System Power Supply Removed (Power
Supply X)
System Power Supplies Not Redundant
Real-Time Clock Battery Failing
A CPU Power Module (System Board,
Socket X)
A CPU Power Module (Slot X, Socket X)
ASR Lockup Detected: Cause
Blue Screen Trap: Cause [NT]
Kernel Panic: Cause [UNIX]
Abnormal Program Termination: Cause
[NetWare]
Automatic Operating System Shutdown
Initiated Due to Fan Failure
Automatic Operating System Shutdown
Initiated Due to Overheat Condition
Fatal Exception (Number X, Cause)
Diagnostics and Troubleshooting 3-49
Action
Replace the processor.
Replace the processor.
Call the service provider or Compaq
for diagnosis.
Power down PCI slot and replace
board
Replace power supply
None
None
Add power supply
Replace battery
Replace power module
Replace power module
Call the service provider or Compaq
for diagnosis.
Refer to the documentation for the
operating system.
Refer to the documentation for the
operating system.