3-10 Compaq ProLiant ML370 Maintenance and Service Guide
Table 3-2
POST Error Messages
Error Code
215 - Processor
Power Module has
lost Redundancy in
Socket x
215 - Nonfunctioning
Voltage Regulator
Module for
Processors
216 - Voltage
Regulator Module for
Processor X no
longer redundant
216 - Processor PPM
has lost Redundancy,
Module X
218 - Cache
Accelerators Not
Installed. System
Halted.
219 - Tag Update
Rules SRAM Failure.
System Halted.
219 - Snoop Rules
SRAM Failure.
System Halted.
220 - Cache
Accelerator Slot x
Initialization Failed.
System Halted.
221 - Power Fault On
Processor Bus X
301 - Keyboard Error
301 - Keyboard Error
or Test Fixture
Installed
continued
Audible Beeps
Probable Source of Problem
None
PPM (DC-DC Converter) has lost
redundancy.
None
PPM (DC-DC Converter) has
failed or lost redundancy.
None
Redundancy failed in PPM
None
Indicated PPM (DC-DC Converter)
has lost redundancy
None
Cache accelerators not installed
or improperly installed
None
Catastrophic chipset failure
None
Catastrophic chipset failure
None
Cache accelerator in slot x
improperly installed or bad
None
A PPM on indicated bus is in a
failed state.
None
Keyboard failure
None
Keyboard failure
Recommended Action
Run Diagnostics. Replace failed
assembly as indicated.
Run Diagnostics. Replace failed
assembly as indicated.
To restore redundancy, replace
the PPM.
Replace failed assembly as
indicated.
Check cache accelerator
installation.
Call Compaq service provider.
Call Compaq service provider.
Check cache accelerator
installation and if properly
installed, replace.
Run Diagnostics. Replace failed
assembly as indicated.
Turn off the computer, then
reconnect the keyboard.
Replace the keyboard.