Table 3-2
POST Error Messages
continued
Error Code
1774 - Slot x Drive
Array—Obsolete
data found in Array
Accelerator.
Select F1 to discard
contents of Array
Accelerator.
Select F2 to write
contents of Array
Accelerator to drives.
1775 - Slot x Drive
Array—ProLiant
Storage System Not
Responding SCSI
Port (y): Check
storage system
power switch and
cables. Turn the
system power off
while checking the
ProLiant power and
cable connections,
then turn the system
power back on to
retry.
Audible Beeps
Probable Source of Problem
None
SMART-2 Controller error
None
Storage system problem
Diagnostics and Troubleshooting 3-17
Recommended Action
Data found in Array Accelerator
is older than data found on
drives. Press F1 to discard the
older data in the Array
Accelerator and retain the
newer data on the drives.
Turn off power to system.
Check external ProLiant power
switch – external drives must all
be powered up before or at the
same time as the main system.
Check cables. If retry does not
help, try replacing the cable,
ProLiant firmware, ProLiant
backplane, or the Smart Array
Controller. Press F1 to resume.