3-22 Compaq ProLiant ML370 Maintenance and Service Guide
Table 3-2
POST Error Messages
Error Code
*1788 - Slot x drive
array reports
incorrect drive
replacement. The
following SCSI
drive(s) should have
been replaced: SCSI
port (y): SCSI ID (x).
The following SCSI
drive(s) were
incorrectly replaced:
SCSI port (y):
SCSI ID (z).
Select F1 to continue
drive array will
remain disabled.
Select F2 to reset
configuration—all
data will be lost.
* The 1788 error message might display inadvertently due to a bad power cable connection to the drive, noise on the
data cable, or a defective SCSI cable. If this message was due to a bad power cable connection, but not incorrect drive
replacement, repair the connection and press F2. If this message is not eliminated by pressing F2, run the Array
Diagnostic Utility (ADU) to resolve.
—Or—
If this message was not due to a bad power cable connection, and no drive replacement took place, this could indicate
noise on the data cable. Check the cable for proper routing.
—Or—
If this message is due to a defective SCSI cable, replace the cable.
continued
Audible Beeps
Probable Source of Problem
None
Drives are not installed in their
original positions, so the drives
have been disabled. See note
below.
Recommended Action
Reinstall the drives correctly, as
indicated.
Press F1 to restart the computer
with the drive array disabled.
—Or—
Press F2 to use the drives as
configured and lose all the data
on them.