Compaq PROLIANT ML370 Maintenance And Service Manual page 91

Compaq server user manual
Hide thumbs Also See for PROLIANT ML370:
Table of Contents

Advertisement

Table 3-16
ADU Diagnostic Messages
Message
Description
Accelerator
At least one line in the cache is no
status: Excessive
longer in use due to excessive ECC
ECC errors
errors detected during use of the
detected in at
memory associated with that cache
least one cache
line.
line. As a result,
at least one
cache line is no
longer in use
Accelerator
During reset initialization obsolete
status: Obsolete
data was found in cache. This was
data detected
due to drives being moved and
written to by another controller.
Accelerator
During reset initialization obsolete
status: Obsolete
data was found in cache and was
data was
discarded (not written to drives).
discarded
Accelerator
During reset initialization obsolete
status: Obsolete
data was found in cache. Obsolete
data was flushed
data was written to the drives, but
(written) to
newer data may have been
drives
overwritten.
Accelerator
Array Accelerator board has been
status:
permanently disabled. It remains
Permanently
disabled until it is reinitialized using
disabled
the Array Configuration Utility (ACU).
Accelerator
Possible data loss detected during
status: Possible
power-up due to all batteries being
data loss in
below sufficient voltage level and no
cache
presence of identification signatures
on the Array Accelerator board.
Accelerator
Array Accelerator board has been
status:
temporarily disabled.
Temporarily
disabled
Accelerator
A status returned from the Array
status:
Accelerator board that ADU does not
Unrecognized
recognize.
status
Accelerator
Valid data was found in posted write
status: Valid data
memory at reinitialization. Data will
found at reset
be flushed to disk.
Accelerator
Catastrophic problem with Array
status: Warranty
Accelerator board. Refer to other
alert
messages on Diagnostics screen for
exact meaning of this message.
continued
Diagnostics and Troubleshooting 3-37
Recommended Action
Replacement of cache should be considered. If
cache replacement is not done remaining cache
lines should continue to operate properly.
Normal operations should continue. The
controller will either write data to the drives or
discard the data completely.
Normal operations should continue.
If newer data was overwritten, you may need to
restore newer data; otherwise, normal
operations should continue.
Check the Disable Code field. Run Array
Configuration Utility (ACU) to reinitialize the
Array Accelerator board.
There is no way to determine if dirty or bad data
was in the cache and is now lost.
Check the Disable Code field.
Obtain the latest version of ADU.
Not an error or data loss condition; no action
required
Replace the Array Accelerator board.