3-38 Compaq ProLiant ML370 Maintenance and Service Guide
Table 3-16
ADU Diagnostic Messages
Message
Adapter/NVRAM
ID mismatch
Array Accelerator
battery pack X
not fully charged
Array Accelerator
battery pack X
below reference
voltage
(recharging)
Board in use by
Expand
operation
Board not
attached
Configuration
signature is zero
Configuration
signature
mismatch
Controller
communication
failure occurred
Controller
detected.
NVRAM
configuration not
present
Controller
firmware needs
upgrading
Controller is
located in
special "video"
slot
continued
Description
Nonvolatile RAM has an ID for a
different controller from the one
physically present in the slot.
Battery is not fully charged.
Battery pack on Array Accelerator is
below required voltage levels.
Array Accelerator memory is in use
by Expand operation.
Array controller configured for use
with Array Accelerator board, but one
is not attached.
ADU detected that nonvolatile RAM
contains a configuration signature of
zero. Old versions of the System
Configuration Utility could cause this.
Array Accelerator board configured
for a different array controller board.
Configuration signature on Array
Accelerator board does not match the
one stored on the array controller
board.
Controller communication failure
occurred.
Nonvolatile RAM does not contain a
configuration for this controller.
Controller firmware is below the
latest recommended version.
Controller is installed in slot for
special video control signals. If
controller is used in this slot, LED
indicators on front panel may not
function properly.
Recommended Action
Run the System Configuration Utility.
If 75% of batteries present are fully charged,
Array Accelerator is fully operational. If less
than 75% of batteries are fully charged, allow
36 hours to recharge them.
Allow enough time for batteries to recharge
(36 hours). If batteries have not recharged
after 36 hours, replace the Array Accelerator
board.
Operate system without Array Accelerator board
until Expand operation completes.
Attach Array Accelerator board to array
controller.
Run the latest version of System Configuration
Utility to configure the controller and nonvolatile
RAM.
To recognize the Array Accelerator board, run
the Array Configuration Utility.
ADU was unable to successfully issue
commands to the controller in this slot.
Run the System Configuration Utility to
configure the nonvolatile RAM.
Run Options ROMPaq to upgrade the controller
to the latest firmware revision.
Install the controller in a different slot and run
the System Configuration Utility to configure the
controller and nonvolatile RAM. Then run the
Array Configuration Utility to configure
controller.