Compaq PROLIANT ML370 Maintenance And Service Manual page 63

Compaq server user manual
Hide thumbs Also See for PROLIANT ML370:
Table of Contents

Advertisement

Table 3-2
POST Error Messages
continued
Error Code
175 - Configuration/
Slot Mismatch Device
Found
177 - Configuration
Not Complete
178 - Processor
Configuration Invalid
180 - Log
Reinitialized
201 - Memory Error
203 - Memory
Address Error
207 - Invalid Memory
Configuration—
Check DIMM [SIMM]
Installation
208 - Invalid Memory
Speed—Check
DIMM [SIMM]
Installation
209 - Memory
Detection Failure.
Check Memory
Installation
211 - Cache Switch
Set Incorrectly
212 - System
Processor Failed/
Mapped out
214 - DC-DC
Converter Failed
214 - Processor PPM
Failed Module X
Audible Beeps
Probable Source of Problem
None
PCI board added, configuration
not updated
None
Incomplete system configuration
None
Processor type or step does not
match configuration memory
None
N/A
None
RAM failure
None
RAM failure
None
Memory module installed
incorrectly
1 long, 1 short
The speed of the memory is too
slow, where: xx00 = expansion
board SIMMs are too slow, or
00yy = system board SIMMs are
too slow. xx and yy have
corresponding bit set
1 long, 1 short
Unable to size memory
None
Switch not set properly during
installation or upgrade
1 short
Processor in slot x failed
None
PowerSafe Module (DC-DC
Converter) failed
None
Indicated PPM (DC-DC Converter)
failed
Diagnostics and Troubleshooting 3-9
Recommended Action
Run the System Configuration
Utility and correct.
Run the System Configuration
Utility and correct.
Run the System Configuration
Utility and correct.
N/A
Run Diagnostics. Replace failed
assembly as indicated.
Run Diagnostics. Replace failed
assembly as indicated.
Verify placement of memory
modules.
The speed of the memory
modules must be 60 ns. Verify
the speed of the memory
modules installed and replace.
Check DIMM installation, and if
error persists, call Compaq
service provider.
Verify switch settings.
Run Diagnostics and replace
failed processor.
Run Diagnostics. Replace failed
assembly as indicated.
Replace failed assembly as
indicated.
continued