3-12 Compaq ProLiant ML370 Maintenance and Service Guide
Table 3-2
POST Error Messages
Error Code
1611 - I/O Fan
(Fan X) failure
detected
1611 - CPU Fan
(Fan X) failure
detected
1612 - Primary
power supply failure
1613 - Low System
Battery
1615 - Power Supply
Failure, Power
Supply Unplugged, or
Power Supply Fan
Failure in Bay X
1617 - Fan controller
not responding
1617 - I/O Fan
controller not
responding
1617 - CPU Fan
controller not
responding
1620 - Locked SCSI
Bus Detected. Verify
SCSI bus cabling.
System halted.
1621 - Current SCSI
bus cable
configuration is not
recommended
1622 - Internal SCSI
Jumper Board Not
Installed
continued
Audible Beeps
Probable Source of Problem
2S
I/O fan has failed
2S
CPU fan has failed
2S
Primary power supply has failed
None
Real time clock system battery is
running low on power
None
A power supply has failed.
2S
Fan controller failure
2S
I/O fan controller failure
2S
CPU fan controller failure
None
SCSI bus failure
None
Improper SCSI bus cabling
None
The system has detected that the
array enabler board is not
installed.
Recommended Action
Replace the failed fan.
Replace the failed fan.
Replace power supply as soon
as possible.
Run Diagnostics. Replace failed
assembly as indicated.
Replace or check specified
power supply.
Check and replace failed
controller assembly.
Check and replace failed
controller assembly.
Check and replace failed
controller assembly.
Run Diagnostics. Replace failed
assembly as indicated.
Check documentation for proper
SCSI bus cabling.
Install the array enabler board.
continued