Table 3-16
ADU Diagnostic Messages
Message
Description
Warning bit
A monitor and performance threshold
detected
violation may have occurred. Status
of a logical drive may not be OK.
Write memory
Data could not be written to cache
error
memory. This typically means that
parity error was detected while
writing data to cache. This could be
caused by incomplete connection
between cache and controller. This is
not a data loss circumstance.
Wrong
This could mean that either the board
Accelerator
was replaced in the wrong slot or
placed in a system that was
previously configured with another
board type. Included with this
message is a message indicating the
type of adapter sensed by ADU and a
message indicating the type of
adapter last configured nonvolatile
RAM.
continued
Diagnostics and Troubleshooting 3-45
Recommended Action
Check the other error messages on the
diagnosis screen for an indication of the
problem.
With power to system turned off, verify that the
cache board is fully connected to controller.
Check the diagnosis screen for other error
messages. Run the System Configuration Utility
to update the system configuration.