Table 3-2
POST Error Messages
continued
Error Code
1797 - Drive Array—
Array Accelerator
Read Error Occurred.
Data in Array
Accelerator has been
lost. Array
Accelerator is
disabled.
1798 - Drive Array—
Array Accelerator
Write Error Occurred.
Array Accelerator is
disabled.
1799 - Drive Array—
Drive(s) Disabled due
to Array Accelerator
Data Loss. Select
"F1" to continue with
logical drives
disabled. Select "F2"
to accept data loss
and to re-enable
logical drives.
Beeps only: 2 Long
Beeps only:
2 Long + 2 Short
(Run System
Configuration Utility -
F10 key)
(RESUME - F1 KEY)
Audible Beeps
Probable Source of Problem
None
Hard parity error while reading
data from posted-writes memory
None
Hard parity error while writing
data to posted-writes memory
None
Volume failed due to loss of data
in posted-writes memory.
2L
No valid memory is present in
the system.
2L, 2S
Power is cycled. Temperature too
hot. Processor fan not installed
or spinning.
None
A configuration error occurred
during POST.
None
As indicated to continue
Diagnostics and Troubleshooting 3-25
Recommended Action
Enable Array Accelerator.
Enable the Array Accelerator.
Press F1 to continue with
logical drives disabled or F2 to
accept data loss and re-enable
logical drives.
Replace failed memory with
valid memory.
Check fans.
Press F10 to run System
Configuration Utility.
Press F1.