3-40 Compaq ProLiant ML370 Maintenance and Service Guide
Table 3-16
ADU Diagnostic Messages
Message
Drive (bay) X is a
replacement
drive marked OK
Drive (bay) X is
failed
Drive (bay) X is
undergoing drive
recovery
Drive (bay) X
needs replacing
Drive (bay) X
upload code not
readable
Drive (bay) X
was
inadvertently
replaced
Drive Monitoring
features are
unobtainable
Drive Monitoring
is NOT enabled
for SCSI Port x
Drive ID x
Drive time-out
occurred on
physical drive
bay X
Drive X indicates
position Y
Duplicate write
memory error
continued
Description
This drive has been replaced and
marked OK by the firmware. This
may occur if a drive has an
intermittent failure (for example, if a
drive has previously failed, and then
when ADU is run, the drive starts
working again).
The indicated physical drive has
failed.
This drive is being rebuilt from the
corresponding mirror or parity data.
The 210-megabyte hard drive has
firmware version 2.30 or 2.31.
An error occurred while ADU was
trying to read the upload code
information from this drive.
The physical drive was incorrectly
replaced after another drive failed.
ADU unable to get monitor and
performance data due to fatal
command problem such as drive
time-out, or unable to get data
because these features are not
supported on the controller.
The monitor and performance
features have not been enabled on
this drive.
ADU issued a command to a physical
drive and the command was never
acknowledged.
Message indicates physical drive that
appears to be scrambled or in a drive
bay other than the one for which it
was originally configured.
Data could not be written to the Array
Accelerator board in duplicate due to
the detection of parity errors. This is
not a data loss situation.
Recommended Action
Replace the drive.
Replace the drive.
Normal operations should resume.
Replace the drive.
If there were multiple errors, this drive may
need to be replaced.
Replace the drive that was incorrectly replaced
and replace the original drive that failed. Do not
run the System Configuration Utility and try to
reconfigure; data will be lost.
Check for other errors (time-outs, and so on). If
no other errors occur, upgrade the firmware to a
version that supports monitor and performance,
if desired.
Run the System Configuration Utility to initialize
the monitor and performance features.
The drive or cable may be bad. Check the other
error messages on the Diagnostics screen to
determine resolution.
Examine the graphical drive representation on
ADU to determine proper drive locations.
Remove drive X and place it in drive position Y.
Rearrange the drives according to the ADU
instructions.
Replace the Array Accelerator board.
continued