Table 3-2
POST Error Messages
continued
Error Code
1731 - Fixed Disk 1
does not support
DMA Mode.
1740 - Fixed Disk 0
failed Set Block
Mode command
1741 - Fixed Disk 1
failed Set Block
Mode command
1750 - Fixed Disk 0
failed Identify
command
1751 - Fixed Disk 1
failed Identify
command
1760 - Fixed Disk 0
does not support
Block Mode
1761 - Fixed Disk 1
does not support
Block Mode
1764 - Slot x Drive Array Capacity Expansion Process is temporarily disabled
(followed by one of the following):
I
Expansion will resume when Array Accelerator has been reattached.
I
Expansion will resume when Array Accelerator has been replaced.
I
Expansion will resume when Array Accelerator RAM allocation is successful.
I
Expansion will resume when Array Accelerator battery reaches full charge.
I
Expansion will resume when automatic data recovery has been completed.
*1766 - Slot x Drive Array requires System ROM Upgrade. Run Systems ROMPaq
Utility.
1767 - Slot x Drive Array Option ROM is Not Programmed Correctly or may Conflict
with the Memory Address Range of an Option Card. Check the Memory Address
Configuration of installed Option Card(s) or run Options ROMPaq Utility to attempt
SMART-2/E Option ROM Reprogramming.
Audible Beeps
Probable Source of Problem
None
Hard drive error
None
Hard drive error
None
Hard drive error
None
Hard drive error
None
Hard drive error
None
Hard drive error
None
Hard drive error
Diagnostics and Troubleshooting 3-15
Recommended Action
Run the System Configuration
Utility and correct.
Run the System Configuration
Utility and correct.
Run the System Configuration
Utility and correct.
Run the System Configuration
Utility and correct.
Run the System Configuration
Utility and correct.
Run the System Configuration
Utility and correct.
Run the System Configuration
Utility and correct.
Reattach or replace Array
Accelerator, wait until the Array
Accelerator batteries have
charged, or for automatic data
recovery to complete, as
indicated.
Run the latest Systems ROMPaq
Utility to upgrade the system
ROMs. Press F1 to resume.
Remove or reconfigure
conflicting Option cards,
especially any cards that are not
recognized by the System
Configuration Utility. Try
reprogramming the ROM on the
SMART-2/E Controller using the
latest Options ROMPaq
(version 2.29 or higher).