Event List

The Event List displays the affected components and the associated error messages. Though the
same basic information displays, the format of the list may differ, depending on how you view
it: on the Integrated Management Display, from within Compaq Insight Manager, or the
Compaq Survey Utility. An example of the format of an event displayed on the Integrated
Management Display follows:
**001 of 010**
---caution---
03/19/1997
12:54 PM
FAN FAILURE
Main System
Location:
System Board
Fan ID: 03
**END OF EVENT**

Event Messages

Event Type
Machine Environment
Fan Failure
Overheat Condition
Main Memory
Correctable Error
threshold exceeded
Uncorrectable Error
Table 3-17

Event Messages

Event Message
System Fan Failure (Fan X, Location)
System Overheating (Zone X, Location)
Corrected Memory Error threshold passed
(Slot X, Memory Module X)
Corrected Memory Error threshold passed
(System Memory)
Corrected Memory Error threshold passed
(Memory Module unknown)
Uncorrectable Memory Error (Slot X,
Memory Module X)
Uncorrectable Memory Error (System
Memory)
Uncorrectable Memory Error (Memory
Module unknown)
Action
Replace fan
Check fans
Replace the defective memory
module.
Replace the memory modules one
at a time (if more than one) and
retest the system.
Replace the memory modules one
at a time (if more than one).
Replace the defective memory
module.
Replace the defective memory
module.
Replace the memory modules one
at a time (if more than one) and
retest the system.