Mantel Requirements

COMBUSTIBLE MANTELS
Combustible mantels may be installed above the fireplace. Use the table below to determine the
minimum height for the mantel being used. The mantel depth (measured from the non-combustible
facing) must fall within the shaded portion of the table.
Any combustible material above the fireplace that protrudes more than 3/4" (19mm) from the non-
combustible facing is considered a combustible mantel and must meet the mantel requirements.

Non-Combustible Mantels

Non-combustible mantels must meet the clearances listed for combustible mantels. However, if you do
wish to reduce the clearances by using a non-combustible mantel, the following requirements must be met:
Non-combustible
mantel and facing
must extend from the
top of the appliance to
the top surface of the
mantel.
A non-combustible
header must be used
(metal stud).
NOTE: If using a CoolSmart TV kit see section "Mantel Clearances with CoolSmart TV" on page 58.
© Travis Industries
Installation
(for qualified installers only)
Non-Combustible Framing (metal studs)
must be used for the header.
9/22/2021 - 1561
SIDE OF FIREPLACE
Drywall
Non-Combustible Mantel
Non-Combustible Facing
35
4237 EG