26
Vent Configuration: Horizontal Terminations using LP
The termination must fall within the shaded area shown in the chart below.
A maximum of 3 elbows (30°, 45°, 60° or 90°) may be used. Only 1 elbow may be a horizontal elbow
(see illustration below).
Horizontal terminations require the high-wind cap (58DVA-HC), vinyl standoff (58DVA-VSS) (on
combustible walls only), and the horizontal termination shield (included with the fireplace).
The high-wind sconce cap is not allowed.
The Snorkel cap is not allowed.
This is considered a
horizontal elbow (it doesn't
matter whether it turns right
or left). It may be a 30°, 45°,
60°, or 90° elbow.
© Travis Industries
Installation
(for qualified installers only)
H2
H1
9/22/2021 - 1561
Horizontal length is calculated by
adding both lengths of horizontal run
(Horizontal Length = H1 + H2).
This is
considered a
vertical elbow.
4237 EG