Directions for Connecting a Gas
Pressure Test Gauge
The gas control valve (shown to the left)
has two accessible ports for testing line
pressure and output pressure. Loosen the
brass screw on either test port and place a
5/16" i.d. rubber or plastic tubing over the
tapered test port. Connect the tubing to the
test gauge.
WARNING: The brass screw must be
tightened after testing to prevent gas
leakage.