Analog Monitor - Mitsubishi Electric MR-J2S B Series Instruction Manual

Servo amplifier
Table of Contents

Advertisement

5. PARAMETERS
Classifi-
No.
Symbol
cation
62
For manufacturer setting
Do not change this value by any means.
63
64
65
66
67
68
69
70
71
72
73
74
75

5.3 Analog monitor

The servo status can be output to two channels in terms of voltage. The servo status can be monitored
using an ammeter.
(1) Setting
Change the following digits of parameter No. 22.
Parameter No. 22
0
0
Parameters No. 27 and 28 can be used to set the offset voltages to the analog output voltages. The
setting range is between
Parameter No.
27
28
Name and Function
Analog monitor 2(MO2) output selection
(Signal output to across MO2-LG)
Analog monitor 1(MO1) output selection
(Signal output to across MO1-LG)
999 and 999mV.
Used to set the offset voltage for the analog monitor 1(MO) output.
Used to set the offset voltage for the analog monitor 2(MO2) output.
Description
5 - 14
Initial
Setting
Unit
Value
Range
0000
400
100
1
1
0
0
0
0
0
0
0
0
0
Setting range [mV]
999 to 999