(Standard mode)
[BCC]
Enable or disable the BCC check function.
Available only if you have selected [STATUS5] in the [Flow Control] menu.
[Delay Reply ENQ]
Set the period to delay status reply to status request command ENQ.
This can be set only if you have selected anything other than [STATUS4] in the [Flow Control] menu.
The setting range is from 0 to 9999 ms.
Normally, keep this setting at the initial value.
[Status4 Cyclic Response]
Set the interval for the cyclic status response.
This can be set only if you have selected [STATUS4] in the [Flow Control] menu.
The setting range is from 100 to 999 ms.
[Proxy (Wi-Fi)]
Set a proxy.
The setting items are as follows:
The proxy set here is shared with the settings in [Interface] > [Network] > [Settings] >
[LAN] > [Proxy (LAN)].
[Enabled]
Enable or disable use of proxy.
To enable a proxy, you need to set [Server] and [Exclude].
[Server]
Set the name or IP address of the proxy server.
Example: http://192.168.1.11:3128
Server should be set with a valid name or IP address and port number.
Hold "." to input a colon (:).