When the communication protocol is STATUS3 or STATUS5, Port1 or Port3 is used.
AEP does not support STATUS3, STATUS4, or STATUS5.
The setting items are as follows:
[Port1]
Set the port number for Port1.
If AEP mode is disabled, and while in the two-port connection of STATUS4, this port is used for
receiving print data. While in the one-port connection of STATUS3/STATUS5, this port is used for both
receiving print data and returning the product status.
While in the two-port connection in AEP mode, this port can be used for both receiving print data and
returning the product status.
The setting range is from 1 to 65535.
Set different values for each port (1, 2, and 3).
Set a value other than 20, 21, 22, 53, 80, 123, 443, 465, 515, 546, 547, 587, 8080,
or 8883. These values duplicate other port numbers, so that correct communications
would be impossible.
AEP does not support STATUS3, STATUS4, or STATUS5.
[Port2]
Set the port number for Port2.
While in the two-port connection of STATUS4, this port is used for returning the product status.
The setting range is from 1 to 65535.
Set different values for each port (1, 2, and 3).
Set a value other than 20, 21, 22, 53, 80, 123, 443, 465, 515, 546, 547, 587, 8080,
or 8883. These values duplicate other port numbers, so that correct communications
would be impossible.
The setting is disabled if [AEP] is enabled.
[Port3]
Set the port number for Port3.
If AEP mode is disabled, and while in the one-port connection of STATUS3/STATUS4/STATUS5, this
port is used for both receiving print data and returning the product status.