Count Total
Shows the total number of times you have written to an RFID tag after the RFID counter is
cleared.
This is the total number including [Count Success] and [Count Failure].
You can reset the counter by tapping [Clear Counters] when the counter is 1 or higher.
[Paper]
Set the print reference position in the vertical direction for RFID tags.
The setting item is as follows:
[Starting Point]
Set the print reference position in the vertical direction for RFID tags.
Set the print reference position by using '+' to move in the feed direction and '-' to move opposite to the
feed direction.
The setting range is from -200 to +200 dots.
The length of 1 dot varies depending on the print resolution of the product.
You can change the units to dots, " (inches), or mm in the [System] > [Regional] >
[Unit] menu.
[SATO RF Analyze]
Set and execute the SATO RF Analyze function, and save the results of the measurements. SATO RF
Analyze is a function of the product that allows you to measure RFID tags and easily set conditions to
consistently write and read them.
The setting items are as follows:
[Search Start]
Execute SATO RF Analyze.
Set the measurement conditions as needed in [Search Level], [Write Power], [Read Power], and [Save
settings] before executing.
Load RFID tags into the product, and tap [Search Start]. Measurement of the RFID tag starts, and the
state of the measurement appears on the screen. Complete the measurement according to the on-
screen instructions.
The length from the leading edge of the tag to the inlay should be 15 mm (0.59") or
more.
The tag length should be 42 mm (1.65") or more (including liner) to execute SATO RF
Analyze.
203 dpi : 1 dot = 0.125 mm (0.0049")
305 dpi : 1 dot = 0.083 mm (0.0033")