Gap
Adjusts the Gap sensor.
I-Mark
Adjusts the I-mark sensor.
Label Top
Adjust the label top sensor.
[Label Top] is not displayed if the optional dispenser unit or linerless cutter unit is
installed.
For media that has no liners, such as wristbands and koDakara, [Label Top] cannot be
adjusted.
The procedure to auto-calibrate the media sensor is as follows:
1. Open the top cover.
2. Load the media.
For adjusting [Gap + I-Mark]/[Gap]/[I-Mark]
Remove the label from the liner and set the liner so the I-mark is not above the I-mark sensor.
For media without liners, such as wristbands or journal paper, load the media as is.
For adjusting [Label Top]
Remove the label from the liner and set the liner so the I-mark is not above the label top
sensor.
3. Close the top cover.
4. Tap the type of sensor from the list to be adjusted.
5. When the confirmation screen appears, tap
If message indicating adjustment failed, load the media correctly and try again.
.
173