MENU PROGRAMMING

MONITOR/CONTACT ACCESS

The MONITOR/CONTACT ACCESS menu defines which
alarm contacts are associated to each monitor in the system.
Five Monitor/Contact Tables can be programmed by this menu,
providing different Monitor/Contact associations. The first
table, Table 0, is the current (active) system Monitor/Contact
arming status. Monitor/Contact Tables 1 - 4 can be written
into (called to) the current Monitor/Contact arming table by
Event Timers only (page 4-10).
The Monitor/Contact Table menu has multiple pages with eight
ACN's per page vertically, and four monitors per page
horizontally. Refer to page 4-3 for menu paging instructions.
M O N C O N TA C T TA B L E - 1
M O N I TO R
A C N
0 0 1
0 0 0 1
N
0 0 0 2
N
0 0 0 3
N
0 0 0 4
N
0 0 0 5
N
0 0 0 6
Y
0 0 0 7
Y
0 0 0 8
N
P R E V I O U S M E N U
The title line of the Monitor/Contact Table menu indicates the
table which is being programmed. If this line displays two
dashes ( - - ), the current, active table is being programmed; if
a number (1 to 4) is displayed, the corresponding
Monitor/Contact Table is being programmed.
The codes for each entry in the menu are:
Y = Alarm Contact is associated to this monitor
N = Alarm Contact is not associated TO this monitor
The above example indicates for Monitor/Contact Table 1:
• Alarm 3 will activate monitor 3's ARM TYPE
• Either alarm 6 or 7 will activate monitor 1's ARM TYPE
1 . K E Y B O A R D / M O N I TO R
2 . K E Y B O A R D / C A M E R A V I E W
3 . K E Y B O A R D / C A M E R A C O N T R O L
4 . M O N I TO R / C A M E R A A C C E S S
5 . M O N I TO R / C O N TA C T A C C E S S
R E T U R N M A I N
0 0 2
0 0 3
0 0 4
N
N
N
N
N
N
N
Y
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
A C C E S S
The Monitor/Contact Tables are set default to N, no contacts
are armed/associated with any monitors. When any keyboard
Monitor Arming commands are performed (see page 3-6),
Monitor/Contact Table 0 is changed to reflect that command.
To select a Monitor/Contact Table for programming:
1. Place the cursor on the MON CONTACT TABLE title line.
2. Enter the table number, 1-4, on the keypad. If no number is
entered, the current active table is selected.
3. Press the ACK key.
To change the alarm contact arming of the selected table:
1. Position the cursor to the alarm contact (ACN) and monitor
entry and that is to be changed.
2. Press the ACK key. When the ACK key is pressed the
current setting toggles between Y = armed, N = not armed.
3. Repeat steps 1 and 2 for any additional changes desired.
4. Position the cursor at the PREVIOUS MENU line.
5. Press the ACK key to return to the main ACCESS Menu,
page 4-22.
Note: DO NOT mix monitor salvos in alarm contact arming.
Monitors used for salvo alarms should not be programmed
for individual alarm contacts.
* Monitors armed to individual alarm contacts should not
be included in salvos that are armed to alarm contacts (via
either the Connect Next or Salvo selections in the Set
Alarm Contacts menu, page 4-12). Such monitors may be
armed to one or more other individual alarm contacts only.
* Monitors included in salvos armed to alarm contacts
(via the Set Alarm Contacts menu, page 4-12) should not be
armed to individual alarm contacts. Such monitors may be
included in other salvos armed for alarm contacts, as long
as all salvos are of equal length (i.e., the same number of
monitors in the salvos).
Note: When arming alarm contacts to a monitor block, arm
the contacts to the first monitor of the block only. DO NOT
arm any contacts to the remaining monitors of a block.