American Dynamics AD2052 System Programming Manual page 37

Megapower ii wip system
Table of Contents

Advertisement

### (Block number) - The block number field associates
monitors together to form a monitor "block" for alarm callup.
A monitor block may consist of any set of system monitors and
need not be contiguous. When a block ARM TYPE is selected
above, the cursor is moved to the Block number field and a
default block number is automatically indicated.
To change or select a block number for this monitor:
1. Place the cursor on the block number (###).
2. Enter the desired block number (1 - 32) on the keypad and
press the ACK key to move to the ACK field.
To set up a block of monitors:
1. Select each monitor via the MONITOR line.
2. Select a block ARM TYPE (e.g., BHI) for this monitor.
3. Select the block number for this monitor, as above.
To add monitors to the block, repeat for each monitor, using
block arming codes and identical block numbers.
Example: Monitor 04 is set for Block #007.
M O N I TO R - 0 4
A R M T Y P E - B H I
TO U R
-
- -
D AT E / T I M E -
T I T L E D I S P L AY -
C A M T I T L E L C K -
M O N T I T L E L C K -
D I S P L AY S TAT U S -
R E T U R N M A I N
Any additional monitors to be included in Block 007 are then
setup with the same ARM TYPE (BHI) and block number
(007) as indicated in the above example.
Refer to the Appendix, pages A-3 to A-7, for further
information on using Monitor Blocks with Alarm Contacts.
ACK - The ACK entry enables or disables the Manual Clear
feature for Instant and Auto Clear arming codes. This feature
must be programmed after the monitor is armed with an
Instant or Auto Clear ARM TYPE.
Press the ACK key to toggle between YES (Enable) or NO
(Disable). Press the NEXT key to lock in the selection.
• YES (ACK Enabled) - When enabled, the letter "A" is
displayed after the Arm Type (e.g., SSI A). The ACK key
clears alarms on this monitor (see page 2-4).
• NO (ACK Disabled) - When disabled, the letter "A" does
not appear after the Arm Type.
Note: The ACK entry cannot be set to NO if a Manual Clear
Arm Type code is programmed for the monitor.
0 0 7
A C K -
TOUR - The TOUR entry indicates the System Tour (1 - 64)
currently associated with this monitor; "--" indicates a Monitor
Tour is associated with the monitor. Enter a System Tour
number and press the ACK key to lock in the selection.
DATE/TIME - The DATE/TIME entry indicates if the
date/time display is ON or OFF for this monitor's on-screen
display. Press the ACK key to toggle the value between ON or
OFF. Press the NEXT key to lock in the selection.
TITLE DISPLAY - The TITLE DISPLAY entry indicates if
the title display is ON or OFF for this monitor's on-screen
display. Press the ACK key to toggle the value between ON or
OFF. Press the NEXT key to lock in the selection.
CAM TITLE LCK - The CAM TITLE LCK entry freezes
the on-screen Camera Title display on this monitor. Press the
ACK key to toggle between LOCKED or UNLOCKED. Press
NEXT key to lock in the selection.
• UNLOCKED - Normal operation. Allows updating of the
Camera Title display with each camera switch.
• LOCKED - Freezes the 16-character alphanumeric title
that is on the monitor on-screen display.
Caution: Once a title is locked it never changes on that
monitor, even if the video is switched. The Camera number
and Status switch, but the 16-character title does not.
MON TITLE LCK - This entry freezes the on-screen Camera
Number and Status display. Press the ACK key to sequence
through LOCKED, UNLOCKED, or CAMERA STATUS.
Press the NEXT key to lock in the selection.
• UNLOCKED - Normal operation. On-screen Camera
Number and Status for that monitor updates at each event.
• LOCKED - Camera Number and Status currently displayed
on the monitor is placed into a locked state.
• CAMERA STATUS - Camera Status for that monitor is
placed into a locked state.
Note: To completely lock the monitor's on-screen display,
place both Camera Title and Monitor Title into the
LOCKED state.
DISPLAY STATUS - The DISPLAY STATUS entry indicates
if the current tour sequencing status is HOLD or RUN. Press
the ACK key to toggle the value between HOLD or RUN.
Press the NEXT key to lock in the selection.
The RETURN MAIN line of the MONITOR menu returns to
the the Main Selection menu, page 4-2.
4-17
MENU PROGRAMMING

Advertisement

Table of Contents
loading

This manual is also suitable for:

2052

Table of Contents