ALARMS - MONITOR ARMING CODES - ARM TYPES
The following are the available Monitor Arming Codes for the
2052. Each is identified by the code number, in parentheses,
and the ARM TYPE letter codes that are displayed in the
Monitor menu, page 4-16.
SINGLE Display, SEQUENCE Queuing
(1) SSI - Single alarm monitor, all armed/alarmed contacts are
queued and sequenced on the monitor. The alarmed
contacts are removed from the queue when the alarm
closure is restored.
(1) SSI A - Single alarm monitor, all armed/alarmed contacts
are queued and sequenced on the monitor. The alarmed
contacts are removed from the queue when the alarm
closure is restored or when the user acknowledges the
alarm.
(2) SSA - Single alarm monitor, all armed/alarmed contacts are
queued and sequenced on the monitor. The alarmed
contacts are removed from the queue 20 seconds after the
alarm closure is restored.
(2) SSA A - Single alarm monitor, all armed/alarmed contacts
are queued and sequenced on the monitor. The alarmed
contacts are removed from the queue 20 seconds after the
alarm closure is restored or when the user acknowledges
the alarm.
(3) SSM - Single alarm monitor, all armed/alarmed contacts
are queued and sequenced on the monitor. The alarmed
contacts are removed only when the user acknowledges
the alarm.
SINGLE Display, HOLD Queuing
(4) SHI - Single alarm monitor, armed/alarmed contacts are
queued and the first alarmed contact is displayed and held
until cleared. The alarmed contacts are removed from the
queue when the alarm closure is restored.
(4) SHI A - Single alarm monitor, armed/alarmed contacts are
queued and the first alarmed contact is displayed and held
until cleared. The alarmed contacts are removed from the
queue when the alarm closure is restored or when the user
acknowledges the alarm.
(5) SHA - Single alarm monitor, armed/alarmed contacts are
queued and the first alarmed contact is displayed and held
until cleared. The alarmed contacts are removed from the
queue 20 seconds after the alarm closure is restored.
(5) SHA A - Single alarm monitor, armed/alarmed contacts are
queued and the first alarmed contact is displayed and held
until cleared. The alarmed contacts are removed from the
queue 20 seconds after the alarm closure is restored or
when the user acknowledges the alarm.
(6) SHM - Single alarm monitor, armed/alarmed contacts are
queued and the first alarmed contact is displayed and held
until cleared. The alarmed contacts are removed only
when the user acknowledges the alarm.
BLOCK Display, SEQUENCE Queuing
(7) BSI - Multiple monitor alarm block, all armed/alarmed
contacts are queued and displayed on monitors with no
existing alarms. When all monitors have alarms, alarmed
contacts sequence evenly on all monitors. The alarmed
contacts are removed from the queue when the alarm
closure is restored.
(7) BSI A - Multiple monitor alarm block, all armed/alarmed
contacts are queued and displayed on monitors with no
existing alarms. When all monitors have alarms, alarmed
contacts sequence evenly on all monitors. The alarmed
contacts are removed from the queue when the alarm
closure is restored or when the user acknowledges the
alarm.
(8) BSA - Multiple monitor alarm block, all armed/alarmed
contacts are queued and displayed on monitors with no
existing alarms. When all monitors have alarms, alarmed
contacts sequence evenly on all monitors. The alarmed
contacts are removed from the queue 20 seconds after the
alarm closure is restored.
(8) BSA A - Multiple monitor alarm block, all armed/alarmed
contacts are queued and displayed on monitors with no
existing alarms. When all monitors have alarms, alarmed
contacts sequence evenly on all monitors. Alarmed
contacts are removed from the queue 20 seconds after the
alarm closure is restored or when the user acknowledges
the alarm.
(9) BSM - Multiple monitor alarm block, all armed/alarmed
contacts are queued and displayed on monitors with no
existing alarms. When all monitors have alarms, alarmed
contacts sequence evenly on all monitors. The alarmed
contacts are removed only when the user acknowledges
the alarm.