Figure 302. Location of the miscellaneous B voltage regulator module LED
Removing a miscellaneous B voltage regulator module from the 9080-M9S
system node
To remove a miscellaneous B voltage regulator module from the 9080-M9S system node system,
complete the steps in this procedure.
Procedure
1. Ensure that you have the electrostatic discharge (ESD) wrist strap on and that the ESD clip is plugged
into a ground jack or connected to an unpainted metal surface. If not, do so now.
2. Remove a miscellaneous B voltage regulator module by completing the following steps:
a) Unlock the levers (A) to release the voltage regulator module from its connector. Refer to the
following image.
b) Rotate the levers in the direction shown.
c) While holding the voltage regulator module by its levers, pull upward to remove the card from its
slot.