Main Setup [200]

11-2-2 Remote Signal Level/Edge [21A]

!Caution
90
In this menu you set the general rotation for the motor.
Default:
R
L
R+L
Communication information
Modbus Instance no/
DeviceNet no:
Profibus slot/index
EtherCAT index (hex)
Fieldbus format
Modbus format
In this menu you select the way to control the inputs for RunR, RunL, Stop and
Reset that are operated via the digital inputs on the terminal strip. The inputs
are default set for level-control, and will be active as long as the input is made
and kept high. When edge-control is selected, the input will be activated by
the low to high transition of the input.
Default:
Level
Edge
Communication information
Modbus Instance no/
DeviceNet no:
Profibus slot/index
EtherCAT index (hex)
Fieldbus format
Modbus format
Level controlled inputs DO NOT comply with the Machine Directive if the
inputs are directly used to start and stop the machine.
Note Edge controlled inputs can comply with the Machine Directive (see the
Chapter SECTION 8 page 65) if the inputs are directly used to start and stop
the machine.
219 Rotation
Stp
A
R + L
Speed direction is limited to right rotation. The input and
1
key RunL are disabled.
Speed direction is limited to left rotation. The input and key
2
RunR are disabled.
3
Both speed directions allowed.
43019
168/178
4bcb
UInt
UInt
21A Level/Edge
Stp
A
Level
The inputs are activated or deactivated by a continuous
0
high or low signal. Is commonly used if, for example, a PLC
is used to operate the VSD.
The inputs are activated by a transition; for Run and Reset
1
from "low" to "high", for Stop from "high" to "low".
43020
168/179
4bcc
UInt
UInt
Section 11-2
R+L
Level