Basic Operation
5-3

Setting the Local/Remote Mode

The 3G3JV operates in local or remote mode. The following description provides in-
formation on these modes and how to select them.
H Basic Concept
Operation mode
Remote
Local
H Local/Remote Selection Methods
• The following two selection methods are available to set the Inverter to local or remote mode. While
the operation command is being input, however, the Inverter cannot be set to local mode from remote
mode or vice versa.
S Select the mode with the LO/RE Key of the Digital Operator.
S Set any one of multi-function inputs 1 through 4 (n36 through n39) to 17 to set the Inverter to local
mode with control input turned ON.
Note If the above setting is made, mode selection will be possible only with multi-function input, and not
with the Digital Operator.
• The Inverter always goes into remote mode when the power is turned ON. Therefore, to operate im-
mediately after power-up, set up the RUN command and frequency reference settings in remote mode
in advance.
5-6
Basic concept
The Inverter in a system
operates according to the
control signal of the host
controller.
The Inverter in a system
operates independently in this
mode so that the Inverter can
be checked independently.
Description
RUN Command
Selectable from two types and set in n02.
Frequency Reference
Selectable from five types and set in n03.
RUN Command
Starts with the RUN Key of the Digital Operator
and stops with the STOP/RESET Key.
Frequency Reference
Set with the Digital Operator or the FREQ
adjuster.
Set with frequency reference selection in local
mode in n07.
Chapter 5