Table 35. Dual V.35 Module Specifications - ADTRAN Total Access 850 System Manual

Adtran total access 850: system manual
Hide thumbs Also See for Total Access 850:
Table of Contents

Advertisement

Total Access 850 System Manual
Table 34. Dual V.35 Interface Pinout (DB-26 to V.35) (Continued)
12
13
14-16
17
18
19
20
21
22
23
24
25
26
Specifications
Table 35 provides the detailed specifications for the Total Access 850 Dual V.35 Module.
Data Rates
Relative Humidity
Cable Assembly
Temperature
Tests
Electrical
Dimensions
Weight
64203376L1-1B
T
Received data (RD-B) to DTE
U
External TX clock (ETC-A) from DTE
Unused
J
Ring indicator (RI)
L
LL
NN
Test mode (TM) to DTE
H
Data terminal ready (DTR) from DTE
Unused
Y
TX clock (TC-A) to DTE
AA
TX clock (TC-B) to DTE
V
RX clock (RC-A) to DTE
X
RX clock (RC-B) to DTE
W
External TX clock (ETC-B) from DTE

Table 35. Dual V.35 Module Specifications

56 kbps to 1.536 Mbps (per interface)
Up to 95% noncondensing
DB-26 to V.35 P/N 1200167L1
Operate at -40 °C to +65 °C
Store at -40 °C to +85 °C
Self-test, DTE loopback, Network
Loopback, 511 Pattern generation
Voltage
-42 to -56 VDC
+3.3 VDC ± 10%
+5.0 VDC ± 5%
-7.5 VDC ± 10%
-24 to -30 VDC
3 3/16" W x 1 5/16" H x 10 1/8" D
4.8 ounces
© 2004 ADTRAN, Inc.
Section 2 Engineering Guidelines
Current
0 mA
20 mA
160 mA
50 mA
0 mA
51

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents