ADTRAN Total Access 850 System Manual page 262

Adtran total access 850: system manual
Hide thumbs Also See for Total Access 850:
Table of Contents

Advertisement

Section 5 DLP-16
Perform the steps below in the order listed.
1. Backplane alarm connections (P5) are labeled as shown in the table below and illustrated in the figure.
1
2
3
4
5
1
2
3
4
5
You will have to remove the cover to access the contacts. Refer to the Total Access 850
rear view illustration on the next page.
262
P3 Wire-Wrap Connections
T1 Connections
R1
DS1 Ring input from network
T1
DS1 Tip input from network
R
DS1 Ring output from network
T
DS1 Tip output from network
Gnd
Ground
P5 Wire-Wrap Connections
Alarm Connections
-48 ALM
DC Alarm output
MJVR
Major Alarm Visual Common
MJV
Major Alarm Visual
MJR
Major Alarm Audible Common
MJ
Major Alarm Audible
To customer designed remote alarms
© 2004 ADTRAN, Inc.
Total Access 850 System Manual
64203376L1-1B

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents