Table 29 provides the detailed specifications for the Total Access 850 UBR1TE Module.
Line
Operating Mode
Data Rate
Signal Format
Transmit Power
BR1/10 compatible equipment.
Interface
Dimensions
Weight
Current Draw
Temperature
Relative Humidity
Heat Dissipation
Compliance Codes
Table 30 provides the compliance codes for the Total Access 850 UBR1TE Module.
CODE
Power Code (PC)
Telecommunication Code (TC)
Installation Code
48

Table 29. UBR1TE Module Specifications

Loop Interface (ANSI T1.601)
2-wire (tip and ring)
full duplex
160 kbps total; 144 kbps available to customer
2B1Q
13 dBm to 14 dBm nominal
DS1 Facility Interface
Network Compatibility
ISDN and other digital service, according to
TR-NWT-000397
Mechanical
3.125" H x 0.62" W, 1.01" D
< 1 lb
Power
0.023 A maximum (@ -48V)
Environmental
Operating: -40 °C to +70 °C
Storage: -40 °C to + 85 °C
Up to 95% noncondensing
1.10 W (maximum)

Table 30. UBR1TE Module Compliance Codes

© 2004 ADTRAN, Inc.