If everything is selected: Always use Purge time Long.
The Drip Tray can be controlled from the Action Bar. The icon reflects the state of the object. Figure
3-12 lists the Drip Tray control icons.
-
Up
-
Down
-
Error (Service)
Set the drip tray down or bring the object up, can be done by clicking the icon
If the drip tray is down, the print sequence sets the drip tray in the upper position.
Always close the front operator cabinet access doors when the drip tray is back in home position. This
prevents the drip tray cover moving toward the Media Input side of the engine due to equipment vibra-
tion. This would trigger an interlock alarm and interrupt the production.
The system must be initialized each time the drip tray leaves its home position.
Agfa Graphics
Jeti Tauro H3300LED Operator Manual
Revision 1.0
Fig.3-10: Purge Time Selection
Fig.3-11: Drip Tray Icons
Chapter 3
22