Chapter 4: Hardware Installation
Figure 20: MTS Mounting Plate
The mounting plate is normally secured directly to the floor.
NOTICE: The use of an insulated base may be considered where additional lightning protection
is required or where local regulations require this (see R56 Manual for further information).
4.4.4.2
Installing the Mounting Plate
When and where to use: Perform this procedure to properly install the mounting plate within the site
facility.
Procedure:
1 Ensure that the mounting plate has been correctly positioned in the equipment room, see
6: Suggested MTS LiTE Site Layout on page 65
Layout on page 66
and
Figure 12: Suggested Expansion Cabinet Site Layout on page 70
2 Use the mounting plate as drilling template or mark the floor according to the dimensions shown
in
Figure 21: MTS LiTE/MTS 2 – Drill Hole Position for the Mounting Plate on page 95
Figure 22: MTS 4 – Drill Hole Position for the Mounting Plate on page
the 13 mm distance behind the mounting plate. Four 12 mm holes are pre-drilled. Additional
holes may be drilled in the mounting plate where required.
94
for MTS 2,
Figure 10: Suggested MTS 4 Site Layout on page 68
for MTS LiTE,
Figure 8: Suggested MTS 2 Site
for Expansion Cabinet.
95. Remember to keep
Figure
for MTS 4,
and