7 Mount the two brackets to the Module cage using 10 pcs. M4 screws.
8 Bend in the area at the back of the Module Cages for Ribbon cables to be routed through later.
15.7.1.2

Assembling the Module Cage in the MTS 4 Cabinet

Procedure:
1 Remove the Module Cage Beauty Plate (if any).
2 Mount all cables going from the lower Module Cage in your specific configuration and fix them
temporarily in the rack before mounting the air separator shelf and module cage.
NOTICE: This would typically be:
Ethernet cables from Base Radio(s) in lower Module Cage to SC in upper Module Cage
(SC2).
Ethernet cables from Base Radio(s) in upper Module Cage to SC in lower Module Cage
(SC1).
CAN Bus cables to and from Filters.
3 Assemble the Air Separator shelf above the existing Module Cage using four M6 screws.
4 Assemble the Module Cage extracted from MTS 2 in
on page
441.
NOTICE: For more information regarding assembling of a module cage in the MTS 4
Cabinet, see Adding Additional Module Cage to MTS 4.
5 Connect the power supply cables and optional backup battery cables.
6 Connect the Ethernet cables and CAN Bus cables mounted in Step 2 above.
7 Switch ON the Power Supply Unit.
8 Check the LED indicators to verify the PSU is operating correctly.
15.7.2

Configuration

No configuration in itself is needed for the module cage, but the Power Supply Unit needs to be
configured and this is described in
Installation and configuration of additional Base Radios are described separately in
Radio for Existing Module Cage in MTS 4 on page
Furthermore, if an additional Site Controller is ordered as a separate expansion kit, it needs to be
installed and configured, see
15.8

Redundant XHUB Controller

It is possible to add an redundant XHUB Controller to an MTS 4 Expansion Cabinet.
NOTICE: In order to be able to expand to a redundant XHUB Controller, a redundant Site
Controller must be present in the MTS 4 Prime Cabinet.
The additional XHUB Controller is delivered with the expansion kit that includes required equipment
and cables.
Updating the Mapping List with the New PSU TrackID on page
423.
Redundant Site Controller on page
Chapter 15: Expansion Options