Updating CAN Bus TrackID Mapping List

When and where to use:
Perform this procedure to update the Mapping List with the New Unit TrackID.
Procedure:
1 Log on to the Site Controller.
2 To view the mapping list, type can check_mapping.
See example below:
SC> can check_mapping
Units are present:
Device Track ID
DPM 1 JTH0500101
PSU 1 JTH0500200
Units are not present:
DPM 2 JTH0500105
Track ID not mapped:
JTH0500102
3 On the list, locate the unit that you have removed and that is indicated as Units are not
present.
4 Delete old CAN Bus unit from the CAN Bus unit mapping list. Type can remove_mapping
<Device>, where <Device> is the old unit name. See example below:
SC> can remove_mapping dpm 2
5 Add new CAN Bus unit to the CAN Bus unit mapping list.
NOTICE: The new unit Track ID is present on the replaced unit label and indicated as
Track ID not mapped in the list shown in
Use can add_mapping <Device> <TrackID>, where< TrackID> is a TrackID of the new
unit and <Device> is the new unit name. Units have the following names: psu X, dpm X, atcc X,
where X denotes a digit between 0 and 3. See example below:
SC> can add_mapping dpm 2 JTH0500102
6 View the updated mapping list using the can check_mapping command and check that there
are no units labeled as Track ID not mapped or Units are not present.
VSWR alarm.
VSWR Alarm Threshold: establishes a threshold for enabling a VSWR
Alarm. Valid threshold values are in the range 1.00 to 10.00 where 1.00
means No VSWR.
Recommended values for each MTS configuration are:
-
400 MHz: 3.00
-
260 MHz: 3.00
800 MHz: 4.00
-